Automated Environmental Chamber BZAE-510
Product1
Product2

Automated Environmental Chamber BZAE-510

Labzee Automated Environmental Chamber BZAE-510 is a precision-built 800L chamber designed for accurate temperature and humidity control. It delivers stable temperatures ranging from 0 to 65°C and humidity levels between 30% and 95% RH. The large LCD screen offers an intuitive interface for configuring and monitoring test conditions in real time. It is equipped with a high-efficiency imported compressor and a dual refrigeration system, supporting continuous, long-duration operation. Our Automated Environmental Chamber BZAE-510 is ideal for pharmaceutical stability testing and climate simulation in demanding R&D environments.

Chamber Volume 800 L
Temperature Range 0 to 65℃
Display Resolution 0.1℃
Temperature Fluctuation Low Temp. ±1℃, High Temp. ±0.5℃
Temperature Uniformity ±1℃
Operating Temperature 5 to 40℃
Humidity Control Range 30% to 95%RH
Humidity Stability ±3%RH
Refrigerant R134a
Continuous Operation Long Continuous Operation
Power Supply AC 220V, 50Hz
Power Consumption 4000 W
Chamber Size (W×D×H) 96.5×61×137 cm
Exterior Size (W×D×H) 110×93×227 cm
Net Weight 185 Kg
Gross Weight 250 Kg
  • Advanced Microprocessor Control
  • User-Friendly Menu Interface
  • Dual-Auto Refrigeration
  • Integrated UV Sterilization
  • Programmable Multi-Segment Control
  • Integrated UV Sterilization
  • Built-In Printer

3 Perforated Shelves (Expandable to 10)

Labzee Automated Environmental Chamber BZAE-510 is ideal for stability testing, accelerated aging, quality control, and environmental simulation in pharmaceutical, food, electronics, materials, and research applications.

captcha

Frequently Asked Questions

1: How does the dual refrigeration system enhance long-term stability testing?

Automated Environmental Chamber BZAE-510 features two independent refrigeration units that automatically alternate operation. This redundancy ensures continuous performance during prolonged testing cycles, minimizing the risk of system downtime due to compressor fatigue or failure.

2: What is the accuracy and stability of temperature and humidity control in this chamber?

Automated Environmental Chamber BZAE-510 delivers temperature uniformity of ±1°C and humidity stability of ±3% RH. With a PID microprocessor and high-accuracy humidity sensor, it ensures precise control and minimal fluctuation even under demanding testing conditions.

3: Can Automated Environmental Chamber BZAE-510 simulate both high- and low-temperature environments for stability testing?

Yes, the temperature control range of 0°C to 65°C allows it to simulate cold storage, ambient, and elevated temperature environments. Fluctuation remains tight—±1°C at lower temperatures and ±0.5°C at higher temperatures.

4: How is humidity generated and managed inside the chamber?

Humidity is controlled using a high-precision international-brand humidity sensor and an internal humidification system. This ensures consistent relative humidity from 30% to 95% RH throughout the chamber’s volume.

5: Is there support for programmable testing protocols?

Yes. Automated Environmental Chamber BZAE-510 includes a digital multi-segment program controller, allowing users to schedule temperature and humidity changes across multiple time segments—ideal for complex, time-dependent stability or stress test protocols.

6: What safety systems are in place to protect test samples and the chamber?

Automated Environmental Chamber BZAE-510 includes a temperature-limiting alarm system that stops operation if temperature exceeds set limits. It also features leakage protection and a backup mechanical thermostat to maintain safety in case of electronic control failure.

7: What kind of user interface does the chamber offer?

Automated Environmental Chamber BZAE-510 features a large LCD display with a menu-driven interface, allowing intuitive control of all key parameters. Users can view temperature, humidity, and program progress in real-time without needing external software.

8: What data recording options are available?

Automated Environmental Chamber BZAE-510 is equipped with a USB port for digital data logging. Users can export test conditions and historical performance for analysis or regulatory reporting. It also supports built-in alarms and status alerts.

9: What is a Constant Climate Chamber?

A Constant Climate Chamber is a laboratory device designed to maintain stable temperature and humidity levels over extended periods. It is commonly used for material testing, stability studies, and environmental simulation under precise, controlled conditions.

10: What temperature and humidity ranges are typically supported?

Our Automated Environmental Chambers operate within a temperature range of 0°C to 65°C and a relative humidity range of 40% to 90% RH, with stability maintained through PID control systems for high accuracy.

11: What applications require constant climate chambers?

Automated Environmental Chambers are widely used in pharmaceutical testing, electronics aging, material degradation analysis, microbiology, cosmetics stability studies, and long-term storage of sensitive samples.

12: How is uniformity ensured inside the chambers?

Automated Environmental Chambers deliver consistent performance with a temperature uniformity of ±1°C, ensuring reliable and stable test conditions throughout the internal workspace.

13: Are these models programmable for complex test cycles?

Yes, Automated Environmental Chambers are equipped with PID programmable controls, allowing users to set and automate multi-step temperature and humidity cycles for advanced testing applications.

14: Do the chambers allow data logging and export?

Yes, Automated Environmental Chambers feature USB-enabled data logging systems that enable users to export, track, and review environmental data for compliance, analysis, and record-keeping.

15: What safety features are built into the units?