Automatic Polarimeter BZPM-512
Product1
Product2

Automatic Polarimeter BZPM-512

Automatic Polarimeter BZPM-512 is high-accuracy polarimeter that features a single-wavelength LED light source for precise optical measurements. It offers advanced Peltier temperature control, ensuring stability and accuracy. This device supports multiple measurement modes, including optical rotation and concentration analysis. It provides a 10.4-inch touch screen with various connectivity options enhances user experience. Our Automatic Polarimeter BZPM-512 includes quartz plates, temperature-controlled tubes, and essential accessories, making it ideal for labs and industries.

Measuring Range ± 90°
Resolution 0.001°/0.0001°
Accuracy ± 0.002°
Repeatability ± 0.001°
Temperature Range 0 to 100°C
Temperature Resolution 0.01°C
Temperature Accuracy ± 0.02°C
Temperature Control Model Peltier
Temperature Control Range 10 to 50°C
Temperature Control Accuracy ± 0.05°C
Sensitivity Minimum 0.01%
Prism Glan Thompson
Light Source LED, 100000 hours
Wavelength 589 nm, 365 nm, 405 nm, 436 nm, 546 nm, 578 nm, 633 nm, 880 nm (one optional)
Measuring Mode Optical rotation,
Temperature Control Platform Up to 200 mm
Interface Network LAN×1, HDMI×1, VGA×1, USB 3.0×2, USB 2.0×1, RS232×1
Display 10.4 Inch touch screen
Configuration Polarimeter, 100mm × 1 (funnel glass tube), 200mm × 1 (funnel glass tube), 100mm × 1 (temperature-controlled metal tube), 200mm × 1 (temperature-controlled metal tube), Printer, +5° Temperature control quartz plate, Syringe, Brush, Power cord, Sampling assistant, Mini dryer, Barcode reader, Key pad set
  • High-Accuracy Optical Measurement
  • Advanced Temperature Control
  • Multiple Measurement Modes
  • User-Friendly Interface
  • Comprehensive Accessories

•    Quartz Plate (Single Plate)
•    Glass Tube 200mm for General Use
•    Glass Tube 100mm for General Use
•    Glass Tube 50mm for General Use
•    Glass Tube 200mm for Sampling Through Funnel
•    Glass Tube 100mm for Sampling Through Funnel
•    Glass  Tube 200mm for Water Bath
•    Glass Tube 50mm for Small Sample
•    Micro-Flow Through Tube 50mm (Stainless Steel)
•    Micro-Flow Through Tube 10mm (Stainless Steel)
•    Special Tube with Hose Connectors (Stainless Steel)
•    Printer
•    Plain Paper
•    Sampling Assistant
•    Mini Dryer
•    Barcode Reader
•    Polarimeter Peltier Consumable Set
•    Quartz Plate with PT1000 Sensor
•    Peltier 200mm set (stainless steel)
•    Peltier 200mm set (anti-corrosion) (HC-276)
•    Peltier 200mm set (anti-corrosion) (Ti)
•    Peltier 100mm set (stainless steel)
•    Peltier 100mm set (anti-corrosion) (HC-276)
•    Peltier 100mm set (anti-corrosion) (Ti)
•    Peltier 50mm set (stainless steel)
•    Peltier 50mm set (anti-corrosion) (HC-276)
•    Peltier 50mm set (anti-corrosion) (Ti)
•    Key pad set
•    QC APP
•    Research APP
•    365nm application package
•    405nm application package

The Automatic Polarimeter BZPM-512 can be used in pharmaceuticals for optical activity measurement and quality control. It helps analyze sugar concentration in food, essential oils, and cosmetics. Additionally, it supports chemical research, biotechnology, and medical studies by analyzing chiral compounds and biomolecules.

captcha

Frequently Asked Questions

1: What types of measurements can BZPM-512 perform?

It supports multiple modes - Optical rotation, Specific rotation, Concentration, International sugar scale (ISS)

2: Is the temperature controlled during measurement?

Yes, it features advanced Peltier temperature control with a range of 10 to 50°C and excellent accuracy, ensuring reliable measurements under stable conditions.

3: Is the device suitable for industrial use?

Yes, with its high accuracy, stability, and robust accessories, the BZPM-512 is ideal for both laboratory and industrial environments.

4: Can I measure substances with very small optical rotation values using this device?

Yes, due to its high resolution (0.001°/0.0001°) and repeatability (±0.001°), the BZPM-512 is well-suited for detecting even minimal changes in optical rotation.

5: Is the device portable?

It is a benchtop model, designed primarily for stationary use in labs or industrial testing areas. It is not intended to be portable.

6: How accurate are your polarimeters?

Our models offer high accuracy, typically ranging from ±0.01° to ±0.002° optical rotation, depending on the model. Contact us for detailed specifications.

7: Is temperature control important in polarimetry?

Yes. Optical rotation is temperature-sensitive, so maintaining a constant temperature (often 20°C or 25°C) using Peltier elements or a water bath ensures accurate and repeatable results.

8: How do you calibrate an automatic polarimeter?

Calibration is usually done using certified quartz control plates or standard solutions with known optical rotation values. Many modern polarimeters also have built-in auto-calibration functions.


Automatic Polarimeter BZPM-512

Automatic Polarimeter BZPM-512